The INVT GD290 Series Variable Frequency Drive (VFD) is designed for efficient industrial motor control across pumps, fans, compressors, conveyors, HVAC systems and process machinery. The model range listed on this page includes IE2-class drive efficiency data, relative-loss values at multiple operating points and standby-loss information for engineering comparison.

As an Authorised INVT Diamond Partner, Integrated Control Solutions supplies genuine INVT GD290 drives across India with model-selection support, quotation assistance, programming guidance, commissioning support, repair assistance and fast delivery.

INVT GD290 Key Benefits

  • IE2 efficiency classification for all models listed in the supplied data.
  • Detailed relative-loss values across multiple operating points.
  • Standby-loss data for energy-performance comparison.
  • Wide model coverage for medium- and high-power industrial applications.
  • Suitable for pumps, fans, HVAC, compressors, conveyors and process machinery.

INVT GD290 Technical Specifications

BrandINVT
SeriesGD290
Product TypeVariable Frequency Drive
Efficiency ClassIE2 for the listed models
Performance DataRelative-loss values and standby-loss values by model
Typical ApplicationsPumps, fans, compressors, HVAC, conveyors and industrial process machinery

Why Buy INVT GD290 From ICS India?

  • Authorised INVT Diamond Partner
  • Genuine INVT products
  • Technical product-selection assistance
  • Pan India supply
  • Programming and commissioning guidance
  • Industrial VFD repair support
  • Fast quotation and delivery assistance

Browse more INVT AC Drives or request an INVT GD290 quotation.

INVT GD290 Model Efficiency and Relative-Loss Table

The following table contains the GD290 model numbers, relative-loss values at the specified operating points, standby loss and IE efficiency class. Confirm all final technical values in the official INVT brochure or manual before product selection.

VFD ModelRelative Loss (%)Standby Loss (W)IE ClassModel Details
(0;25)(0;50)(0;100)(50;25)(50;50)(50;100)(90;50)(90;100)
GD290-7R5G/011P-40.811.071.710.831.521.831.622.0825IE2View details
GD290-011G/015P-40.630.871.590.651.361.701.451.9427IE2View details
GD290-015G/018P-40.781.011.551.291.551.831.642.0630IE2View details
GD290-018G/022P-40.720.951.431.201.441.721.521.9730IE2View details
GD290-022G/030P-40.831.051.881.311.892.051.972.1230IE2View details
GD290-030G/037P-40.710.981.761.221.831.961.922.0730IE2View details
GD290-037G/045P-40.450.611.121.051.231.871.472.0630IE2View details
GD290-045G/055P-4(-B)0.630.941.481.181.551.911.742.0631IE2View details
GD290-055G/075P-4(-B)0.520.801.351.061.421.841.671.9632IE2View details
GD290-075G/090P-4(-B)0.420.691.040.981.191.721.451.9133IE2View details
GD290-090G/110P-4(-B)0.500.731.280.971.121.741.332.0332IE2View details
GD290-110G/132P-4(-B)0.420.691.200.840.981.671.271.9534IE2View details
GD290-132G/160P-40.701.141.501.441.511.911.582.0334IE2View details
GD290-160G-40.641.051.411.351.421.871.492.0035IE2View details
GD290-185P-40.611.011.321.261.331.821.421.9736IE2View details
GD290-200P-40.530.981.281.211.291.791.371.9437IE2View details
GD290-185G-40.650.911.451.141.251.921.342.0138IE2View details
GD290-200G-40.480.811.330.991.081.891.281.9939IE2View details
GD290-220P-40.470.791.300.961.051.871.241.9640IE2View details
GD290-250P-40.410.751.280.891.011.821.191.9142IE2View details
GD290-220G-40.721.011.871.351.711.921.792.0043IE2View details
GD290-250G-40.680.981.921.271.561.881.621.9444IE2View details
GD290-280G-40.660.941.881.191.471.831.561.9145IE2View details
GD290-280P-40.630.871.711.081.391.791.481.8948IE2View details
GD290-315P-40.610.841.671.021.311.741.421.8750IE2View details
GD290-355P-40.570.781.630.981.291.711.371.8452IE2View details
GD290-315G-40.720.851.641.141.381.861.431.9650IE2View details
GD290-355G-40.700.821.521.081.271.831.371.9352IE2View details
GD290-400G-40.690.781.400.901.101.791.251.8955IE2View details
GD290-400P-40.660.731.320.881.071.761.211.8555IE2View details
GD290-450P-40.630.701.270.841.021.731.161.8358IE2View details
GD290-500P-40.600.681.230.810.971.691.111.8060IE2View details

INVT GD290 Model Details

Scroll horizontally to compare all GD290 model numbers, relative-loss data, standby loss and IE efficiency class.

INVT GD290-7R5G/011P-4 VFD

Full ModelGD290-7R5G/011P-4
Search AliasGD290-7R5G/011P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.81%
Relative Loss (0;50)1.07%
Relative Loss (0;100)1.71%
Relative Loss (50;25)0.83%
Relative Loss (50;50)1.52%
Relative Loss (50;100)1.83%
Relative Loss (90;50)1.62%
Relative Loss (90;100)2.08%
Standby Loss25 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-011G/015P-4 VFD

Full ModelGD290-011G/015P-4
Search AliasGD290-011G/015P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.63%
Relative Loss (0;50)0.87%
Relative Loss (0;100)1.59%
Relative Loss (50;25)0.65%
Relative Loss (50;50)1.36%
Relative Loss (50;100)1.70%
Relative Loss (90;50)1.45%
Relative Loss (90;100)1.94%
Standby Loss27 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-015G/018P-4 VFD

Full ModelGD290-015G/018P-4
Search AliasGD290-015G/018P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.78%
Relative Loss (0;50)1.01%
Relative Loss (0;100)1.55%
Relative Loss (50;25)1.29%
Relative Loss (50;50)1.55%
Relative Loss (50;100)1.83%
Relative Loss (90;50)1.64%
Relative Loss (90;100)2.06%
Standby Loss30 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-018G/022P-4 VFD

Full ModelGD290-018G/022P-4
Search AliasGD290-018G/022P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.72%
Relative Loss (0;50)0.95%
Relative Loss (0;100)1.43%
Relative Loss (50;25)1.20%
Relative Loss (50;50)1.44%
Relative Loss (50;100)1.72%
Relative Loss (90;50)1.52%
Relative Loss (90;100)1.97%
Standby Loss30 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-022G/030P-4 VFD

Full ModelGD290-022G/030P-4
Search AliasGD290-022G/030P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.83%
Relative Loss (0;50)1.05%
Relative Loss (0;100)1.88%
Relative Loss (50;25)1.31%
Relative Loss (50;50)1.89%
Relative Loss (50;100)2.05%
Relative Loss (90;50)1.97%
Relative Loss (90;100)2.12%
Standby Loss30 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-030G/037P-4 VFD

Full ModelGD290-030G/037P-4
Search AliasGD290-030G/037P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.71%
Relative Loss (0;50)0.98%
Relative Loss (0;100)1.76%
Relative Loss (50;25)1.22%
Relative Loss (50;50)1.83%
Relative Loss (50;100)1.96%
Relative Loss (90;50)1.92%
Relative Loss (90;100)2.07%
Standby Loss30 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-037G/045P-4 VFD

Full ModelGD290-037G/045P-4
Search AliasGD290-037G/045P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.45%
Relative Loss (0;50)0.61%
Relative Loss (0;100)1.12%
Relative Loss (50;25)1.05%
Relative Loss (50;50)1.23%
Relative Loss (50;100)1.87%
Relative Loss (90;50)1.47%
Relative Loss (90;100)2.06%
Standby Loss30 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-045G/055P-4 VFD

Full ModelGD290-045G/055P-4(-B)
Search AliasGD290-045G/055P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.63%
Relative Loss (0;50)0.94%
Relative Loss (0;100)1.48%
Relative Loss (50;25)1.18%
Relative Loss (50;50)1.55%
Relative Loss (50;100)1.91%
Relative Loss (90;50)1.74%
Relative Loss (90;100)2.06%
Standby Loss31 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-055G/075P-4 VFD

Full ModelGD290-055G/075P-4(-B)
Search AliasGD290-055G/075P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.52%
Relative Loss (0;50)0.80%
Relative Loss (0;100)1.35%
Relative Loss (50;25)1.06%
Relative Loss (50;50)1.42%
Relative Loss (50;100)1.84%
Relative Loss (90;50)1.67%
Relative Loss (90;100)1.96%
Standby Loss32 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-075G/090P-4 VFD

Full ModelGD290-075G/090P-4(-B)
Search AliasGD290-075G/090P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.42%
Relative Loss (0;50)0.69%
Relative Loss (0;100)1.04%
Relative Loss (50;25)0.98%
Relative Loss (50;50)1.19%
Relative Loss (50;100)1.72%
Relative Loss (90;50)1.45%
Relative Loss (90;100)1.91%
Standby Loss33 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-090G/110P-4 VFD

Full ModelGD290-090G/110P-4(-B)
Search AliasGD290-090G/110P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.50%
Relative Loss (0;50)0.73%
Relative Loss (0;100)1.28%
Relative Loss (50;25)0.97%
Relative Loss (50;50)1.12%
Relative Loss (50;100)1.74%
Relative Loss (90;50)1.33%
Relative Loss (90;100)2.03%
Standby Loss32 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-110G/132P-4 VFD

Full ModelGD290-110G/132P-4(-B)
Search AliasGD290-110G/132P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.42%
Relative Loss (0;50)0.69%
Relative Loss (0;100)1.20%
Relative Loss (50;25)0.84%
Relative Loss (50;50)0.98%
Relative Loss (50;100)1.67%
Relative Loss (90;50)1.27%
Relative Loss (90;100)1.95%
Standby Loss34 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-132G/160P-4 VFD

Full ModelGD290-132G/160P-4
Search AliasGD290-132G/160P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.70%
Relative Loss (0;50)1.14%
Relative Loss (0;100)1.50%
Relative Loss (50;25)1.44%
Relative Loss (50;50)1.51%
Relative Loss (50;100)1.91%
Relative Loss (90;50)1.58%
Relative Loss (90;100)2.03%
Standby Loss34 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-160G-4 VFD

Full ModelGD290-160G-4
Search AliasGD290-160G-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.64%
Relative Loss (0;50)1.05%
Relative Loss (0;100)1.41%
Relative Loss (50;25)1.35%
Relative Loss (50;50)1.42%
Relative Loss (50;100)1.87%
Relative Loss (90;50)1.49%
Relative Loss (90;100)2.00%
Standby Loss35 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-185P-4 VFD

Full ModelGD290-185P-4
Search AliasGD290-185P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.61%
Relative Loss (0;50)1.01%
Relative Loss (0;100)1.32%
Relative Loss (50;25)1.26%
Relative Loss (50;50)1.33%
Relative Loss (50;100)1.82%
Relative Loss (90;50)1.42%
Relative Loss (90;100)1.97%
Standby Loss36 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-200P-4 VFD

Full ModelGD290-200P-4
Search AliasGD290-200P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.53%
Relative Loss (0;50)0.98%
Relative Loss (0;100)1.28%
Relative Loss (50;25)1.21%
Relative Loss (50;50)1.29%
Relative Loss (50;100)1.79%
Relative Loss (90;50)1.37%
Relative Loss (90;100)1.94%
Standby Loss37 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-185G-4 VFD

Full ModelGD290-185G-4
Search AliasGD290-185G-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.65%
Relative Loss (0;50)0.91%
Relative Loss (0;100)1.45%
Relative Loss (50;25)1.14%
Relative Loss (50;50)1.25%
Relative Loss (50;100)1.92%
Relative Loss (90;50)1.34%
Relative Loss (90;100)2.01%
Standby Loss38 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-200G-4 VFD

Full ModelGD290-200G-4
Search AliasGD290-200G-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.48%
Relative Loss (0;50)0.81%
Relative Loss (0;100)1.33%
Relative Loss (50;25)0.99%
Relative Loss (50;50)1.08%
Relative Loss (50;100)1.89%
Relative Loss (90;50)1.28%
Relative Loss (90;100)1.99%
Standby Loss39 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-220P-4 VFD

Full ModelGD290-220P-4
Search AliasGD290-220P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.47%
Relative Loss (0;50)0.79%
Relative Loss (0;100)1.30%
Relative Loss (50;25)0.96%
Relative Loss (50;50)1.05%
Relative Loss (50;100)1.87%
Relative Loss (90;50)1.24%
Relative Loss (90;100)1.96%
Standby Loss40 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-250P-4 VFD

Full ModelGD290-250P-4
Search AliasGD290-250P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.41%
Relative Loss (0;50)0.75%
Relative Loss (0;100)1.28%
Relative Loss (50;25)0.89%
Relative Loss (50;50)1.01%
Relative Loss (50;100)1.82%
Relative Loss (90;50)1.19%
Relative Loss (90;100)1.91%
Standby Loss42 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-220G-4 VFD

Full ModelGD290-220G-4
Search AliasGD290-220G-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.72%
Relative Loss (0;50)1.01%
Relative Loss (0;100)1.87%
Relative Loss (50;25)1.35%
Relative Loss (50;50)1.71%
Relative Loss (50;100)1.92%
Relative Loss (90;50)1.79%
Relative Loss (90;100)2.00%
Standby Loss43 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-250G-4 VFD

Full ModelGD290-250G-4
Search AliasGD290-250G-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.68%
Relative Loss (0;50)0.98%
Relative Loss (0;100)1.92%
Relative Loss (50;25)1.27%
Relative Loss (50;50)1.56%
Relative Loss (50;100)1.88%
Relative Loss (90;50)1.62%
Relative Loss (90;100)1.94%
Standby Loss44 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-280G-4 VFD

Full ModelGD290-280G-4
Search AliasGD290-280G-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.66%
Relative Loss (0;50)0.94%
Relative Loss (0;100)1.88%
Relative Loss (50;25)1.19%
Relative Loss (50;50)1.47%
Relative Loss (50;100)1.83%
Relative Loss (90;50)1.56%
Relative Loss (90;100)1.91%
Standby Loss45 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-280P-4 VFD

Full ModelGD290-280P-4
Search AliasGD290-280P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.63%
Relative Loss (0;50)0.87%
Relative Loss (0;100)1.71%
Relative Loss (50;25)1.08%
Relative Loss (50;50)1.39%
Relative Loss (50;100)1.79%
Relative Loss (90;50)1.48%
Relative Loss (90;100)1.89%
Standby Loss48 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-315P-4 VFD

Full ModelGD290-315P-4
Search AliasGD290-315P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.61%
Relative Loss (0;50)0.84%
Relative Loss (0;100)1.67%
Relative Loss (50;25)1.02%
Relative Loss (50;50)1.31%
Relative Loss (50;100)1.74%
Relative Loss (90;50)1.42%
Relative Loss (90;100)1.87%
Standby Loss50 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-355P-4 VFD

Full ModelGD290-355P-4
Search AliasGD290-355P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.57%
Relative Loss (0;50)0.78%
Relative Loss (0;100)1.63%
Relative Loss (50;25)0.98%
Relative Loss (50;50)1.29%
Relative Loss (50;100)1.71%
Relative Loss (90;50)1.37%
Relative Loss (90;100)1.84%
Standby Loss52 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-315G-4 VFD

Full ModelGD290-315G-4
Search AliasGD290-315G-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.72%
Relative Loss (0;50)0.85%
Relative Loss (0;100)1.64%
Relative Loss (50;25)1.14%
Relative Loss (50;50)1.38%
Relative Loss (50;100)1.86%
Relative Loss (90;50)1.43%
Relative Loss (90;100)1.96%
Standby Loss50 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-355G-4 VFD

Full ModelGD290-355G-4
Search AliasGD290-355G-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.70%
Relative Loss (0;50)0.82%
Relative Loss (0;100)1.52%
Relative Loss (50;25)1.08%
Relative Loss (50;50)1.27%
Relative Loss (50;100)1.83%
Relative Loss (90;50)1.37%
Relative Loss (90;100)1.93%
Standby Loss52 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-400G-4 VFD

Full ModelGD290-400G-4
Search AliasGD290-400G-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.69%
Relative Loss (0;50)0.78%
Relative Loss (0;100)1.40%
Relative Loss (50;25)0.90%
Relative Loss (50;50)1.10%
Relative Loss (50;100)1.79%
Relative Loss (90;50)1.25%
Relative Loss (90;100)1.89%
Standby Loss55 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-400P-4 VFD

Full ModelGD290-400P-4
Search AliasGD290-400P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.66%
Relative Loss (0;50)0.73%
Relative Loss (0;100)1.32%
Relative Loss (50;25)0.88%
Relative Loss (50;50)1.07%
Relative Loss (50;100)1.76%
Relative Loss (90;50)1.21%
Relative Loss (90;100)1.85%
Standby Loss55 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-450P-4 VFD

Full ModelGD290-450P-4
Search AliasGD290-450P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.63%
Relative Loss (0;50)0.70%
Relative Loss (0;100)1.27%
Relative Loss (50;25)0.84%
Relative Loss (50;50)1.02%
Relative Loss (50;100)1.73%
Relative Loss (90;50)1.16%
Relative Loss (90;100)1.83%
Standby Loss58 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

INVT GD290-500P-4 VFD

Full ModelGD290-500P-4
Search AliasGD290-500P-4
SeriesINVT GD290
BrandINVT
Relative Loss (0;25)0.60%
Relative Loss (0;50)0.68%
Relative Loss (0;100)1.23%
Relative Loss (50;25)0.81%
Relative Loss (50;50)0.97%
Relative Loss (50;100)1.69%
Relative Loss (90;50)1.11%
Relative Loss (90;100)1.80%
Standby Loss60 W
Efficiency ClassIE2
Typical ApplicationsIndustrial pumps, fans, compressors, conveyors, HVAC and process machinery

Selection notice: Confirm motor current, voltage, duty type, overload requirement, operating conditions and official technical specifications before ordering.

INVT GD290 Applications

  • Industrial pumps and process pumps
  • Ventilation and industrial fans
  • HVAC systems
  • Compressors
  • Conveyor systems
  • Process machinery
  • Water-treatment systems
  • Industrial automation

INVT GD290 Manual, Catalogue and Datasheet

Download the official INVT GD290 catalogue and installation manual using the buttons at the top of this product page. The documentation should be used to confirm electrical ratings, wiring, installation, option codes, parameters, commissioning and troubleshooting information.

The documentation applies to models including GD290-022G/030P-4, GD290-110G/132P-4, GD290-220G-4, GD290-315G-4 and other GD290 models listed on this page.

Frequently Asked Questions About INVT GD290 VFD

Find answers about GD290 efficiency data, standby loss, model selection, manuals, quotations and technical support.

What is the INVT GD290 Series VFD?

The INVT GD290 is a variable frequency drive designed for industrial motor control and energy-efficient operation across pumps, fans, compressors, conveyors, HVAC and process machinery.

What does IE2 mean for the GD290?

IE2 identifies the drive efficiency class shown in the technical data provided for the listed GD290 models.

What are relative loss values?

Relative loss values indicate drive losses at different operating points. They are useful when comparing energy performance under varying speed and torque conditions.

What is standby loss?

Standby loss is the electrical power consumed when the drive is energized but not actively delivering motor output.

Which GD290 model has a 25 W standby loss?

The GD290-7R5G/011P-4 model is listed with a standby loss of 25 W.

What is the GD290-022G/030P-4 model?

The GD290-022G/030P-4 is a GD290 Series model with IE2 efficiency classification and a listed standby loss of 30 W.

Which GD290 models include the -B option?

The provided table includes -B variants such as GD290-045G/055P-4(-B), GD290-055G/075P-4(-B), GD290-075G/090P-4(-B), GD290-090G/110P-4(-B) and GD290-110G/132P-4(-B).

Where can I download the GD290 manual?

Use the Product Manual button at the top of the product page to access the official GD290 installation, wiring, parameter and commissioning documentation.

Where can I download the GD290 catalogue?

Use the Product Brochure button at the top of the product page to access official model, performance and technical data.

How do I select the correct GD290 model?

Selection should consider motor power, rated current, voltage, duty type, overload requirement, application, installation environment and the exact ordering code.

Can I request a GD290 quotation by model number?

Yes. Use the Request Quote or WhatsApp button for the specific GD290 model and share the motor details, quantity and application.

Does ICS India provide technical support for GD290?

Integrated Control Solutions provides product-selection and technical assistance. Programming, commissioning and site support depend on the project scope.

Need Help Selecting the Correct GD290 Model?

Share your motor power, rated current, voltage, application and required quantity with the ICS India technical team.